PLC ENGINEERING

KCD2-SOT-2.SP Isolated Barrier

Home

Pepperl+Fuchs

KCD2-SOT-2.SP Isolated Barrier

KCD2-SOT-2.SP Isolated Barrier

The Pepperl+Fuchs KCD2-SOT-2.SP is an isolated barrier designed for safe and reliable signal processing in industrial automation systems. 

HS CODE : 8428909090

  • Product No :

    KCD2-SOT-2.SP
  • Manufacture :

    Pepperl Fuchs
  • Size (cm) :

    12.46*2.25*11.45
  • Weight (kg) :

    0.2
  • Origin :

    Singapore
  • Warranty :

    12 Month
  • Lead Time :

    Ready Stock
  • Description :

    Processor Unit

Key Features:

Function:

The KCD2-SOT-2. SP is a two-channel switch amplifier used to process and transmit signals from hazardous areas to safe areas.  It is suitable for use with sensors or switches and provides an output that can control devices in the non-hazardous area.

Input:

Channels: Two independent input channels.

Designed to accept signals from NAMUR sensors, dry contacts, or other digital input devices located in hazardous environments.

Output:

Provides two relay outputs, one for each input channel.

Each relay output is used to control devices such as alarms, actuators, or control logic in the safe area.

The "SP" suffix typically indicates that the relay outputs have safety-related features or are compliant with specific safety standards, ensuring reliable operation in critical applications.

Power Supply: Operates on a 24 V DC power supply.

Relay Type:

Normally open (NO) relay contacts.

Rated for specific current and voltage suitable for the intended application.

Mounting:

Designed for DIN rail mounting, allowing easy installation in control panels or industrial cabinets.

Dimensions:

Width: 22.5 mm

Height: 114.5 mm

Depth: 124.6 mm

Weight: Approximately 200g.

Applications:

Used in process control systems where reliable signal transmission and control are essential, particularly in industries like oil & gas, chemical processing, and pharmaceuticals.

Suitable for applications requiring safety features, such as emergency shutdown systems or safety alarms.

Certifications:

The KCD2-SOT-2. SP is certified for use in hazardous areas with approvals like ATEX and IECEx, ensuring it meets international safety standards.

It is likely rated for SIL (Safety Integrity Level) applications, providing additional assurance for safety-critical systems.

Summary:

The KCD2-SOT-2. SP is a dual-channel isolated barrier with relay outputs designed to safely transmit and control signals between hazardous and non-hazardous areas.  It offers robust signal isolation and safety features, making it ideal for industrial applications where safety and reliability are critical.

All items are Distributor Ready-stock Genuine Brand-new Supplying, please inform us if the other conditions are needed, Used, Open-box, Refurbished, etc.

Allen Bradley - CompactLogix; ControlLogix, Flex I/O, MicroLogix, etc.

Siemens - Simatic S7-300; S7-400; S7-1200; S7-1500; HMI 6AV etc.

ABB - Advant 800xA S800; S200; S400; S500; S600; S700; S900 etc.

GE Fanuc - 90-30; 90-70; PACSystems RX3i, etc.

Honeywell - Experion® PKS; ControlEdge™ HC900; etc.

Many Available just wait for you, feel free to ask to get better deal!!!
Bou L
Sales Specialist
[email protected]
+86-175 5077 6091

Conditions

Original Brand New

Approximate Lead Time

3-5 days

Warranty

One Year

Online Service

 7/24

Express Company

DHL / FedEx / UPS / TNT etc.

MOQ

1 Piece

TZ Tech is not an authorized surplus dealer or affiliate for the Manufacturer of this product.
The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because TZ Tech is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.
While many PLC products will have firmware already installed, TZ Tech makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application.

TZ Tech also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source.
TZ Tech also makes no representations as to your right to install any such firmware on the product.
TZ Tech will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related Products

KCD2-SOT-Ex2 barrier
KCD2-SOT-Ex2 Pepperl Fuchs Switch Amplifier
The KCD2-SOT-Ex2 is a switch amplifier used for intrinsic safety applications. HS CODE : 8538909200
More +
KCD2-SOT-Ex1.LB P+F
KCD2-SOT-Ex1.LB Pepperl Fuchs Switch Amplifier
The KCD2-SOT-Ex1. LB is a 1-channel isolated barrier switch amplifier used for intrinsic safety applications.  It is designed to transfer digital signals (NAMUR sensors or dry contacts) from a hazardous area to a safe area. HS CODE : 8538909200
More +
KCD2-SR-Ex1.LB barrier
KCD2-SR-Ex1.LB Pepperl Fuchs Switch Amplifier
KCD2-SR-Ex1.LB is a model number for a signaling conditioners module manufactured by Pepperl+Fuchs. It is designed for use in hazardous areas and is part of their K-System line of products. HS CODE : 8538909200
More +
KCD2-SR-Ex2 barrier
KCD2-SR-Ex2 Pepperl Fuchs Switch Amplifier
The KCD2-SR-Ex2 is a 2-channel isolated barrier switch amplifier used for intrinsic safety applications. It is designed to transfer digital signals (NAMUR sensors or dry contacts) from a hazardous area to a safe area. HS CODE : 8538909200
More +
KFD2-ER-Ex1.W.LB barrier
KFD2-ER-Ex1.W.LB Pepperl Fuchs Conductive Switch Amplifier
The KFD2-ER-Ex1.W. LB is a conductivity switch amplifier manufactured by Pepperl+Fuchs.  It is an isolated barrier used for intrinsic safety applications, providing the AC measuring voltage for the level sensing electrodes.  HS CODE : 8538909200
More +
KFD2-SH-Ex1 p+f
KFD2-SH-Ex1 Pepperl Fuchs Switch Amplifier
The KFD2-SH-Ex1 is a 1-channel isolated barrier switch amplifier manufactured by Pepperl+Fuchs.  It is designed for use in intrinsic safety applications, transferring digital signals from hazardous areas to safe areas.   HS CODE : 8538909200
More +
KFD2-SH-Ex1.T.OP barrier
KFD2-SH-Ex1.T.OP Pepperl Fuchs Switch Amplifier
The KFD2-SH-Ex1.T. OP is a switch amplifier manufactured by Pepperl+Fuchs.  It is a 1-channel isolated barrier with a 24 V DC supply (Power Rail) and is designed for intrinsic safety applications. HS CODE : 8538909200
More +
KFD2-SOT3-Ex1.LB barrier
KFD2-SOT3-Ex1.LB Pepperl Fuchs Switch Amplifier
The KFD2-SOT3-Ex1. LB is a 1-channel isolated barrier switch amplifier manufactured by Pepperl+Fuchs, designed for use in intrinsic safety applications.  It is used to transfer digital signals from a hazardous area to a safe area.  HS CODE : 8538909200
More +
Subscribe

Please read on, stay posted, subscribe, and we welcome you to tell us what you think.

submit
Copyright 2024 @ TZ TECH Co., LTD. .All Rights Reserved Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Sitemap | Blog | XML | Privacy Policy

leave a message

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
submit

Home

Products

whatsApp

contact

YOUR COOKIE SETTINGS

In addition, with your permission, we want to place cookies to make your visit anointeraction with slOC more personal. For this we use analytical and advertisingcookies. With these cookies we and third parties can track and collect yourinternet behawior inside and outside super-instrument.com. With this we and third parties adapt super-instrument.com and advertisementsto your interest. By clicking Accept you agree to this. If you decline, we only usethe necessary cookies and you unfortunately will not receive any personalizedcontent. Please visit our Cookie policy for more information or to change yourconsent in the future.

Accept and continue Decline cookies