KCD2-SCD-1. SP Signal Conditioning Device
The KCD2-SCD-1. SP is a signal conditioning device from Pepperl+Fuchs, specifically designed to work in industrial automation environments, particularly those that may involve hazardous areas. This model is part of their K-System, which is well-known for providing reliable intrinsic safety solutions, signal conditioning, and isolation.
HS CODE : 8428909090
Product No :
KCD2-SCD-1. SPManufacture :
Pepperl FuchsSize (cm) :
11.4*1.25*10Weight (kg) :
0.1Origin :
SingaporeWarranty :
12 MonthLead Time :
Ready StockDescription :
Processor UnitFunctionality:
The KCD2-SCD-1. SP is primarily used for signal conditioning, providing the necessary isolation and conversion of signals from field devices to be compatible with control systems like PLCs (Programmable Logic Controllers) or DCSs (Distributed Control Systems).
Inputs:
The device typically accepts standard analog signals, such as 4-20 mA current loops or 0-10 V voltage inputs. These signals are common in process control and automation systems.
Outputs:
The module provides a conditioned output signal that matches the input but is isolated and converted to a form suitable for further processing by control systems.
Intrinsic Safety:
Designed for use in hazardous environments, the KCD2-SCD-1. SP ensures that any energy within the circuit is restricted to prevent the possibility of ignition in explosive atmospheres, making it compliant with safety standards like ATEX and IECEx.
Galvanic Isolation:
It provides galvanic isolation between the input, output, and power supply, which is crucial for maintaining signal integrity, preventing electrical noise, and protecting the control system from potential surges.
Power Supply:
The module operates on a standard 24 V DC power supply, a common requirement in industrial automation environments.
Mounting:
The KCD2-SCD-1. SP is designed for easy installation on a DIN rail, which is standard in most industrial control panels.
Certifications:
The device is certified for use in hazardous areas, adhering to international safety standards, ensuring it can be safely deployed in environments with explosive gases, vapors, or dust.
Applications:
Signal Conditioning and Isolation:
The KCD2-SCD-1. SP is used to ensure that analog signals from field devices are correctly conditioned and isolated before being sent to control systems, ensuring accurate data processing and reliable system operation.
Industrial Automation:
Suitable for a wide range of industrial automation tasks, especially in environments where intrinsic safety is required.
Process Control:
Ideal for use in process control applications where monitoring and controlling various processes require precise signal conditioning and isolation.
All items are Distributor Ready-stock Genuine Brand-new Supplying, please inform us if the other conditions are needed, Used, Open-box, Refurbished, etc.
Allen Bradley - CompactLogix; ControlLogix, Flex I/O, MicroLogix, etc.
Siemens - Simatic S7-300; S7-400; S7-1200; S7-1500; HMI 6AV etc.
ABB - Advant 800xA S800; S200; S400; S500; S600; S700; S900 etc.
GE Fanuc - 90-30; 90-70; PACSystems RX3i, etc.
Honeywell - Experion® PKS; ControlEdge™ HC900; etc.
Many Available just wait for you, feel free to ask to get better deal!!!
Bou L
Sales Specialist
[email protected]
+86-175 5077 6091
Conditions |
Original Brand New |
Approximate Lead Time |
3-5 days |
Warranty |
One Year |
Online Service |
7/24 |
Express Company |
DHL / FedEx / UPS / TNT etc. |
MOQ |
1 Piece |
TZ Tech is not an authorized surplus dealer or affiliate for the Manufacturer of this product.
The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because TZ Tech is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.
While many PLC products will have firmware already installed, TZ Tech makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application.
TZ Tech also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source.
TZ Tech also makes no representations as to your right to install any such firmware on the product.
TZ Tech will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Sitemap | Blog | XML | Privacy Policy
In addition, with your permission, we want to place cookies to make your visit anointeraction with slOC more personal. For this we use analytical and advertisingcookies. With these cookies we and third parties can track and collect yourinternet behawior inside and outside super-instrument.com. With this we and third parties adapt super-instrument.com and advertisementsto your interest. By clicking Accept you agree to this. If you decline, we only usethe necessary cookies and you unfortunately will not receive any personalizedcontent. Please visit our Cookie policy for more information or to change yourconsent in the future.
Accept and continue Decline cookies