FC-TSHART-1620M Honeywell FSC HART 16CH AI FTA
The Honeywell FC-TSHART-1620M is a 16-channel analog input module designed for HART protocol devices, capable of receiving analog signals from multiple field devices and communicating bidirectional with the devices via HART. It is suitable for industrial automation and process control systems, providing stable and reliable signal acquisition and equipment management functions.
HS CODE : 8538909200
Product No :
FC-TSHART-1620MManufacture :
HoneywellSize (cm) :
21.1 * 14 * 3.8Weight (kg) :
0.35Origin :
USAWarranty :
12 MonthLead Time :
Ready StockDescription :
ModuleMain features:
16-channel analog input (AI) : The FC-TSHART-1620M provides 16 channel analog input, which can be connected to a variety of field devices, such as sensors, transmitters, etc., to collect analog signals sent by devices.
Each channel can typically support 4-20mA or other standard analog signals.
HART Protocol Support: This module supports the HART (Highway Addressable Remote Transducer) protocol, a digital communication protocol widely used in industrial automation.
HART protocol provides digital signal function, so that the device can not only transmit the traditional analog signal, but also achieve two-way communication with the device through the digital signal (such as remote diagnosis, equipment configuration, etc.).
Field Terminal Assembly (FTA) : The FC-TSHART-1620M integrates the field terminal Assembly (FTA) function, which provides an interface for signal transmission between the field equipment and the control system, simplifying installation, wiring, and maintenance.
High reliability and anti-interference: The module design has high reliability and can withstand strong electrical noise and interference in the industrial environment to ensure the stable acquisition of analog signals.
Redundant and fault-tolerant design: Like other Honeywell security modules, the FC-TSHART-1620M also supports redundant configurations to improve system reliability and fault tolerance.
Self-diagnosis function: Provides self-diagnosis function, which can monitor the status of modules and input signals in real time, find faults and alarm in time, and help operation and maintenance personnel to repair or replace them in time.
Application scenario:
Process control and automation system: It is used to connect various field sensors, transmitters and other devices, collect and transmit their analog and digital signals to the control system.
HART equipment communication: It is widely used in the equipment that needs to communicate through the HART protocol, such as pressure sensors, flowmeters, temperature sensors, etc.
Industrial field equipment monitoring and diagnosis: Support equipment diagnosis function, remote configuration and monitoring equipment status, improve operation and maintenance efficiency.
All items are Distributor Ready-stock Genuine Brand-new Supplying, please inform us if the other conditions are needed, Used, Open-box, Refurbished, etc.
Allen Bradley - CompactLogix; ControlLogix, Flex I/O, MicroLogix, etc.
Siemens - Simatic S7-300; S7-400; S7-1200; S7-1500; HMI 6AV etc.
ABB - Advant 800xA S800; S200; S400; S500; S600; S700; S900 etc.
GE Fanuc - 90-30; 90-70; PACSystems RX3i, etc.
Honeywell - Experion® PKS; ControlEdge™ HC900; etc.
Many Available just wait for you, feel free to ask to get better deal!!!
Bou L
Sales Specialist
[email protected]
+86-175 5077 6091
Conditions |
Original Brand New |
Approximate Lead Time |
3-5 days |
Warranty |
One Year |
Online Service |
24 / 7 |
Express Company |
DHL / FedEx / UPS / TNT etc. |
MOQ |
1 Piece |
TZ Tech is not an authorized surplus dealer or affiliate for the Manufacturer of this product.
The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because TZ Tech is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.
While many PLC products will have firmware already installed, TZ Tech makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application.
TZ Tech also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source.
TZ Tech also makes no representations as to your right to install any such firmware on the product.
TZ Tech will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Sitemap | Blog | XML | Privacy Policy
In addition, with your permission, we want to place cookies to make your visit anointeraction with slOC more personal. For this we use analytical and advertisingcookies. With these cookies we and third parties can track and collect yourinternet behawior inside and outside super-instrument.com. With this we and third parties adapt super-instrument.com and advertisementsto your interest. By clicking Accept you agree to this. If you decline, we only usethe necessary cookies and you unfortunately will not receive any personalizedcontent. Please visit our Cookie policy for more information or to change yourconsent in the future.
Accept and continue Decline cookies