FC-SDIL-1608 Honeywell ELM 16CH SAFE DIGITAL I/O LM MODULE
The FC-SCL-1608 is a secure digital input/output module for security applications in Honeywell Experion PKS systems.
HS CODE : 8538909200
Product No :
FC-SDIL-1608Manufacture :
HoneywellSize (cm) :
19 * 12.8 * 2Weight (kg) :
0.16Origin :
USAWarranty :
12 MonthLead Time :
Ready StockDescription :
ModuleMain functions:
Secure digital input/output with 16 channels: The FC-SDIL-1608 provides 16 channels supporting digital input (DI) and digital output (DO), which are used to connect devices in the secure system, such as switches, sensors and actuators.
The module is designed to meet high safety standards and is used to collect safety-related digital signals to ensure the safety of the system.
SIL Safety Level compliance: The module meets the SIL 2 (safety Integrity Level 2) or SIL 3 (depending on configuration and application scenario) safety standards for safety-critical applications.
By providing a redundant design and fault detection mechanism, the system can maintain high reliability in the event of failure.
Security features: The FC-SCL-1608 provides real-time digital input and output control in security applications. These signals are commonly used in emergency shutdown systems (ESD), safety instrumentation systems (SIS), etc.
With this digital I/O capability, systems can quickly respond to security incidents, perform emergency operations or shut down related equipment to protect people and assets.
Redundancy and fault tolerance: The module supports redundant design and has high fault tolerance. In the event of a channel or module failure, the redundant system can automatically switch to the standby device to ensure the continuous operation of the safety system.
Diagnosis and health monitoring: Provides self-diagnosis and health monitoring functions to check the operating status of the module in real time, detect potential faults and give feedback through the alarm or reporting system to enhance the reliability of the system.
Technical specifications:
Input/Output type: 16-channel digital input/output for security control systems.
Compliance: Meets safety standards such as IEC 61508 and IEC 61511 and supports safety levels such as SIL 2 or SIL 3.
Power requirements: 24 VDC standard industrial power input.
Redundant design: With redundant configuration to ensure high availability.
Application scenario:
Safety Instrumentation systems (SIS) : Safety instrumentation systems used in industrial facilities to ensure automatic equipment shutdown, emergency shutdown, and other operations in the event of danger.
Emergency Shutdown system (ESD) : Used to perform emergency shutdown operations in high-risk environments such as oil, gas, and chemicals.
Safety control in process control systems: suitable for safety-critical applications in oil, gas, chemical, power and other industries.
The FC-SCL-1608, Honeywell's secure digital I/O module for Experion PKS systems, supports 16 digital input/output channels and is designed for security control and high-risk applications. The modules comply with SIL 2/SIL 3 safety standards and are designed for redundancy and fault diagnosis and are widely used in industrial environments requiring high safety, such as oil, gas and chemical industries.
All items are Distributor Ready-stock Genuine Brand-new Supplying, please inform us if the other conditions are needed, Used, Open-box, Refurbished, etc.
Allen Bradley - CompactLogix; ControlLogix, Flex I/O, MicroLogix, etc.
Siemens - Simatic S7-300; S7-400; S7-1200; S7-1500; HMI 6AV etc.
ABB - Advant 800xA S800; S200; S400; S500; S600; S700; S900 etc.
GE Fanuc - 90-30; 90-70; PACSystems RX3i, etc.
Honeywell - Experion® PKS; ControlEdge™ HC900; etc.
Many Available just wait for you, feel free to ask to get better deal!!!
Bou L
Sales Specialist
[email protected]
+86-175 5077 6091
Conditions |
Original Brand New |
Approximate Lead Time |
3-5 days |
Warranty |
One Year |
Online Service |
24 / 7 |
Express Company |
DHL / FedEx / UPS / TNT etc. |
MOQ |
1 Piece |
TZ Tech is not an authorized surplus dealer or affiliate for the Manufacturer of this product.
The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because TZ Tech is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.
While many PLC products will have firmware already installed, TZ Tech makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application.
TZ Tech also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source.
TZ Tech also makes no representations as to your right to install any such firmware on the product.
TZ Tech will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Sitemap | Blog | XML | Privacy Policy
In addition, with your permission, we want to place cookies to make your visit anointeraction with slOC more personal. For this we use analytical and advertisingcookies. With these cookies we and third parties can track and collect yourinternet behawior inside and outside super-instrument.com. With this we and third parties adapt super-instrument.com and advertisementsto your interest. By clicking Accept you agree to this. If you decline, we only usethe necessary cookies and you unfortunately will not receive any personalizedcontent. Please visit our Cookie policy for more information or to change yourconsent in the future.
Accept and continue Decline cookies