900RTA-L001 Honeywell ControlEdge HC900 ANALOG INPUT RTP Module
The 900RTA-L001 is the Honeywell ControlEdge HC900 series I/O Terminal Assembly for field device connectivity and management in ControlEdge HC900 systems. It provides an efficient terminal access point for industrial automation control systems to connect I/O modules to field equipment for data acquisition and control.
HS CODE : 8538909200
Product No :
900RTA-L001Manufacture :
HoneywellSize (cm) :
13.7 * 3.6 * 1Weight (kg) :
0.35Origin :
USAWarranty :
12 MonthLead Time :
Ready StockDescription :
ModuleFeatures:
I/O Terminal wiring: The 900RTA-L001 serves as the I/O Terminal Assembly and provides the physical connection point between the I/O module in the ControlEdge HC900 system and the field equipment. It provides the user with a clear and simple connection interface, and simplifies the connection process between the field equipment and the control system.
Support for multiple I/O modules: The terminal patch board can be used with a variety of I/O modules, such as digital input (DI), digital output (DO), analog input (AI), analog output (AO) and other types of modules, capable of handling a variety of field signals.
Simplify field wiring: With this terminal patch board, users can easily connect field devices to I/O modules. It provides convenient terminals for field equipment, and helps reduce wiring errors and reduce the complexity of field wiring.
Enhanced system reliability: By providing reliable terminals and standardized wiring solutions, the 900RTA-L001 improves system reliability and stability and reduces failures caused by improper wiring.
Modular design: The 900RTA-L001 adopts a modular design, which can be flexibly expanded according to the application requirements, and is compatible with other HC900 series modules, which enhances the scalability of the system.
Technical parameters:
Type: This is an I/O terminal patch board used to connect the field equipment to the I/O module in the ControlEdge HC900 system.
Supported module types: Support a variety of I/O modules such as digital input, digital output, analog input and analog output, to meet different types of on-site signal access needs.
Terminal: Provides standardized terminal to simplify the wiring process between the field equipment and the control system to ensure the accuracy and safety of the wiring.
Operating voltage: When used with the ControlEdge HC900 system, a 24V DC power supply is usually required.
Working environment: Temperature range: 0°C to 60°C, suitable for the working conditions of industrial environment.
Humidity range: 5% to 95% (non-condensing).
Mounting method: DIN rail mounting for quick installation and maintenance in the control cabinet.
Application scenario:
Industrial automation control: 900RTA-L001 is used in industrial automation control systems to connect field sensors, actuators and other equipment, and input their signals to the HC900 control system for real-time monitoring and control.
Data Acquisition and remote monitoring: Where a large number of field equipment connections and data acquisition are required, the 900RTA-L001 provides a standardized, easy-to-wire solution to facilitate the transmission of equipment signals to the control system.
Distributed Control System (DCS) : In a distributed control system (DCS), the 900RTA-L001 can help connect various devices in the field and enable centralized management and control of equipment at multiple remote sites through the ControlEdge HC900 controller.
Connection between the field device and the control system: In the automation system, the 900RTA-L001 serves as the I/O terminal board to provide an effective connection between the field device and the control system, reducing the complexity of wiring and ensuring the stable operation of the system.
Advantages:
Simplified field wiring: Standardized terminals are provided to make the wiring process of field equipment simpler and faster, reducing the possibility of wiring errors.
Improve system reliability: Through reliable wiring connections, the failure caused by improper wiring is reduced, and the overall stability and reliability of the system is improved.
Modularity and scalability: As part of the ControlEdge HC900 system, the 900RTA-L001 supports a modular design for easy expansion and customization to meet the needs of systems of different sizes.
Easy installation and maintenance: The DIN rail installation is convenient and fast, which is convenient for on-site installation and future maintenance, reducing operation and maintenance costs.
The Honeywell 900RTA-L001 is the ControlEdge HC900 series I/O terminal patch board for connecting field equipment to I/O modules in the HC900 control system. It provides standardized terminals, simplifies the field wiring process, and enhances the reliability and stability of the system. By supporting multiple types of I/O modules, it is widely used in industrial automation, distributed control systems (DCS) and other scenarios that require field device connectivity.
All items are Distributor Ready-stock Genuine Brand-new Supplying, please inform us if the other conditions are needed, Used, Open-box, Refurbished, etc.
Allen Bradley - CompactLogix; ControlLogix, Flex I/O, MicroLogix, etc.
Siemens - Simatic S7-300; S7-400; S7-1200; S7-1500; HMI 6AV etc.
ABB - Advant 800xA S800; S200; S400; S500; S600; S700; S900 etc.
GE Fanuc - 90-30; 90-70; PACSystems RX3i, etc.
Honeywell - Experion® PKS; ControlEdge™ HC900; etc.
Many Available just wait for you, feel free to ask to get better deal!!!
Bou L
Sales Specialist
[email protected]
+86-175 5077 6091
Conditions |
Original Brand New |
Approximate Lead Time |
3-5 days |
Warranty |
One Year |
Online Service |
24 / 7 |
Express Company |
DHL / FedEx / UPS / TNT etc. |
MOQ |
1 Piece |
TZ Tech is not an authorized surplus dealer or affiliate for the Manufacturer of this product.
The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because TZ Tech is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.
While many PLC products will have firmware already installed, TZ Tech makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application.
TZ Tech also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source.
TZ Tech also makes no representations as to your right to install any such firmware on the product.
TZ Tech will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Sitemap | Blog | XML | Privacy Policy
In addition, with your permission, we want to place cookies to make your visit anointeraction with slOC more personal. For this we use analytical and advertisingcookies. With these cookies we and third parties can track and collect yourinternet behawior inside and outside super-instrument.com. With this we and third parties adapt super-instrument.com and advertisementsto your interest. By clicking Accept you agree to this. If you decline, we only usethe necessary cookies and you unfortunately will not receive any personalizedcontent. Please visit our Cookie policy for more information or to change yourconsent in the future.
Accept and continue Decline cookies