6DP1210-8BC is a FUM 210 Module in the Siemens TELEPERM XP series for signal processing and data acquisition, which can convert analog signals from field equipment to digital signals or adjust them. Ensure accurate control and real-time response of the Teleperm XP system. The module is suitable for industrial automation, process control, intelligent manufacturing, energy management and other fields, and can provide high-precision signal processing and real-time data monitoring, providing powerful support for complex industrial applications.
HS CODE : 8538909200
Product No :
6DP1210-8BC 6DP12108BCManufacture :
SiemensSize (cm) :
28 * 28 * 3Weight (kg) :
0.5Origin :
GermanyWarranty :
12 MonthLead Time :
Ready StockDescription :
ModuleMain functions:
Signal processing and conversion: The core function of the FUM 210 module is to collect, convert and adjust analog signals (such as temperature, pressure, flow, etc.) from field equipment.
It converts analog signals into digital signals, or processes digital signals and provides them to the control system for further analysis.
Data acquisition and monitoring: The module can collect sensor data in real time and ensure data accuracy and reliability through signal conditioning and conversion functions, suitable for complex industrial environments.
Support high frequency data acquisition and real-time processing to ensure rapid and stable system response.
Integration with other modules: The FUM 210 module is integrated with other modules in the TELEPERM XP system (such as control units, communication modules, I/O modules, etc.) to achieve flexible system expansion and configuration.
It can interconnect with other modules through standard interfaces to ensure smooth data flow and signal processing of the system.
Precise control and regulation: The module supports precise regulation of analog input signals, such as gain regulation, filtering, etc., thus ensuring that the Teleperm XP system can accurately control industrial processes.
It handles input signals very carefully and can meet the strict requirements of signal quality and system response in process control systems.
Technical specifications:
Parameter description
Module Type FUM 210 Module
Function signal processing, data acquisition and conversion
Input types Support multiple types of analog signal inputs (such as temperature, pressure, flow, etc.)
Output Type Digital signal Output or analog signal after processing
Operating voltage 24V DC (common voltage)
Operating temperature range 0°C to 60°C
Protection class IP20
Dimensions Standard dimensions suitable for installation in the Teleperm XP system cabinet
Compatibility Compatible with Siemens Teleperm XP series systems and related modules
Application scenario:
Industrial automation systems: The FUM 210 module is widely used in industrial automation systems, especially in the need for signal acquisition and processing, such as sensor networks, production line monitoring and equipment condition monitoring.
It can convert analog signals from the field (such as temperature, pressure, etc.) into digital signals for the control system to use, ensuring that the system can respond in real time and make control decisions.
Process control systems: In process control systems in the chemical, metallurgical, energy and other industries, the FUM 210 module is used to collect and convert data from field instruments (such as temperature, flow, pressure sensors) to ensure accurate control and optimal operation of the system.
Intelligent manufacturing: The FUM 210 module has a wide range of applications in intelligent manufacturing, especially in automated production lines that require accurate data acquisition and processing.
It provides the system with stable signal conditioning and data conversion, helping to achieve a high degree of automation and optimization of production.
Energy Management and Smart Grid: In energy management and smart grid systems, the FUM 210 can be used to collect and process power equipment data in real time, and transmit the data to the monitoring system for processing and decision-making, helping to optimize grid operation and energy distribution.
Equipment monitoring and diagnosis: In equipment monitoring and fault diagnosis systems, the FUM 210 module is used to collect machine status data, such as vibration, temperature, etc., to help identify potential faults by processing and analyzing the data to ensure the safety and efficiency of equipment operation.
All items are Distributor Ready-stock Genuine Brand-new Supplying, please inform us if the other conditions are needed, Used, Open-box, Refurbished, etc.
Allen Bradley - CompactLogix; ControlLogix, Flex I/O, MicroLogix, etc.
Siemens - Simatic S7-300; S7-400; S7-1200; S7-1500; HMI 6AV etc.
ABB - Advant 800xA S800; S200; S400; S500; S600; S700; S900 etc.
GE Fanuc - 90-30; 90-70; PACSystems RX3i, etc.
Honeywell - Experion® PKS; ControlEdge™ HC900; etc.
Many Available just wait for you, feel free to ask to get better deal!!!
Bou L
Sales Specialist
[email protected]
+86-175 5077 6091
Conditions |
Original Brand New |
Approximate Lead Time |
3-5 days |
Warranty |
One Year |
Online Service |
24 / 7 |
Express Company |
DHL / FedEx / UPS / TNT etc. |
MOQ |
1 Piece |
TZ Tech is not an authorized surplus dealer or affiliate for the Manufacturer of this product.
The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because TZ Tech is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.
While many PLC products will have firmware already installed, TZ Tech makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application.
TZ Tech also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source.
TZ Tech also makes no representations as to your right to install any such firmware on the product.
TZ Tech will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Sitemap | Blog | XML | Privacy Policy
In addition, with your permission, we want to place cookies to make your visit anointeraction with slOC more personal. For this we use analytical and advertisingcookies. With these cookies we and third parties can track and collect yourinternet behawior inside and outside super-instrument.com. With this we and third parties adapt super-instrument.com and advertisementsto your interest. By clicking Accept you agree to this. If you decline, we only usethe necessary cookies and you unfortunately will not receive any personalizedcontent. Please visit our Cookie policy for more information or to change yourconsent in the future.
Accept and continue Decline cookies